Pulp and Paper Canada

Features Research & Innovation
COGENERATION: Windsor Cogeneration Specifications

Turbine Supplier HITACHIContractor SNC-LAVALINTURBINEMaximum power output32 MWAnnual average output25 MWInlet pressure (TT valve)4.2...

February 1, 2002  By Pulp & Paper Canada


Turbine Supplier HITACHI

Contractor SNC-LAVALIN

TURBINE

Advertisement

Maximum power output 32 MW
Annual average output 25 MW
Inlet pressure (TT valve) 4.263 MPa(a)
Inlet temperature 395 Celsius
Max flow 430 t/h

Extraction (section)

Extraction pressure 1683 MPa(a)
Extraction temperature 288 Celsius
Steam extraction capability flow 120 t/h

Exhaust (Section)

Exhaust pressure (design) 0.869 MPa(a)
Exhaust temperature 226 Celsius
Steam exhaust-capability flow 340 t/h
Normal speed 3600 RPM
Drive direct
Type Impulse
Number of stages 6
Governor GE MarkVI
Voltage output (generator) 13.8 kV
Step-up transformer 13.8/120 kV
Synchronization Automatic